LZN's Blog CodePlayer

WRF SST Update problem solved

2018-07-10
LZN
   

When I tried to use the realtime SST update in WRF runtime, I met the problem:

 None of the following are allowed to be TRUE :
  ( internal_time_loop .EQ. 1 )                F   
  ( config_flags%grid_fdda .NE. 0 )            F   
  ( config_flags%sst_update .EQ. 1 )           T   
  ( config_flags%all_ic_times )                F   
  ( config_flags%smooth_cg_topo )              F   
  ( config_flags%polar )                       F   
-------------- FATAL CALLED ---------------
FATAL CALLED FROM FILE:  <stdin>  LINE:     431 
 Problems, we cannot have excluded middle data from WPS 

delete namelist variable in namelist.wps

 process_only_bdy = 5

and rebuild the met_em* files.

Updated 2018-07-18